Whaley Modular Chillers are ideal for retrofit installations to replace old, worn out air cooled chillers where pumps and reservoirs are already in existence. Modular chillers can be installed in series and staged in as needed depending upon current load needs. Pump Tank Systems are available as well. contact an experienced modular chiller engineer. |
208-230/460/3 Single Circuit 25 Ton – 50 Ton
Unit Specifications
Model #
|
Tonnage
|
KW
|
BTU/hr
|
Voltage
|
GPM
|
Compressors
|
Unit Amps
(1 On Comp) |
Unit Amps
(2 On Comps) |
SAE25-3 |
25 Ton
|
87.75
|
300,000
|
208-230/3
|
60
|
2
|
54.7
|
109.4
|
SAE25-4 |
25 Ton
|
87.75
|
300,000
|
460/3
|
60
|
2
|
21.9
|
43.8
|
SAE30-3 |
30 Ton
|
105.3
|
360,000
|
208-230/3
|
72
|
2
|
62.4
|
124.8
|
SAE30-4 |
30 Ton
|
105.3
|
360,000
|
460/3
|
72
|
2
|
30.2
|
60.4
|
SAE40-3 |
40 Ton
|
140.4
|
480,000
|
208-230/3
|
96
|
3
|
57.9
|
173.7
|
SAE40-4 |
40 Ton
|
140.4
|
480,000
|
460/3
|
96
|
3
|
26.4
|
79.2
|
SAE50-3 |
50 Ton
|
175.5
|
600,000
|
208-230/3
|
120
|
3
|
62.4
|
187.2
|
SAE50-4 |
50 Ton
|
175.5
|
600,000
|
460/3
|
120
|
3
|
30.2
|
90.6
|
Single Circuit Physical Specifications
Model #
|
Tonnage
|
KW
|
Voltage
|
Length
|
Width
|
Height
|
# of
Compressors |
Inlet/Outlet
Connections |
SAE25-3 |
25 Ton
|
87.75
|
208-230/3
|
102″
|
44″
|
68″
|
2
|
2″
|
SAE25-4 |
25 Ton
|
87.75
|
460/3
|
102″
|
44″
|
68″
|
2
|
2″
|
SAE30-3 |
30 Ton
|
105.3
|
208-230/3
|
102″
|
44″
|
80″
|
2
|
2″
|
SAE30-4 |
30 Ton
|
105.3
|
460/3
|
102″
|
44″
|
80″
|
2
|
2″
|
SAE40-3 |
40 Ton
|
140.4
|
208-230/3
|
108″
|
92″
|
80″
|
3
|
3″
|
SAE40-4 |
40 Ton
|
140.4
|
460/3
|
108″
|
92″
|
80″
|
3
|
3″
|
SAE50-3 |
50 Ton
|
175.5
|
208-230/3
|
108″
|
92″
|
80″
|
3
|
3″
|
SAE50-4 |
50 Ton
|
175.5
|
460/3
|
108″
|
92″
|
80″
|
3
|
3″
|
208-230/460/3 Dual Circuit 25 Ton – 50 Ton
Model #
|
Tonnage
|
KW
|
BTU/hr
|
Voltage
|
GPM
|
Compressors
|
FLA
Circuit A |
FLA
Circuit B |
Unit FLA
|
SAE25D-3 |
25 Ton
|
87.75
|
300,000
|
208-230/3
|
60
|
2
|
54.7
|
54.7
|
109.4
|
SAE25D-4 |
25 Ton
|
87.75
|
300,000
|
460/3
|
60
|
2
|
21.9
|
21.9
|
43.8
|
SAE30D-3 |
30 Ton
|
105.3
|
360,000
|
208-230/3
|
72
|
2
|
62.4
|
62.4
|
124.8
|
SAE30D-4 |
30 Ton
|
105.3
|
360,000
|
460/3
|
72
|
2
|
30.2
|
30.2
|
60.4
|
SAE40D-3 |
40 Ton
|
140.4
|
480,000
|
208-230/3
|
96
|
4
|
84.8
|
80
|
164.8
|
SAE40D-4 |
40 Ton
|
140.4
|
480,000
|
460/3
|
96
|
4
|
42.4
|
40
|
82.4
|
SAE50D-3 |
50 Ton
|
175.5
|
600,000
|
208-230/3
|
120
|
4
|
115.8
|
115.8
|
231.6
|
SAE50D-4 |
50 Ton
|
175.5
|
600,000
|
460/3
|
120
|
4
|
52.8
|
52.8
|
105.6
|
Dual Circuit Physical Specifications
Model #
|
Tonnage
|
KW
|
Voltage
|
Length
|
Width
|
Height
|
# of
Compressors |
Inlet/Outlet
Connections |
SAE25D-3 |
25 Ton
|
87.75
|
208-230/3
|
102″
|
44″
|
68″
|
2
|
2″
|
SAE25D-4 |
25 Ton
|
87.75
|
460/3
|
102″
|
44″
|
68″
|
2
|
2″
|
SAE30D-3 |
30 Ton
|
105.3
|
208-230/3
|
102″
|
44″
|
80″
|
2
|
2″
|
SAE30D-4 |
30 Ton
|
105.3
|
460/3
|
102″
|
44″
|
80″
|
2
|
2″
|
SAE40D-3 |
40 Ton
|
140.4
|
208-230/3
|
108″
|
92″
|
80″
|
4
|
3″
|
SAE40D-4 |
40 Ton
|
140.4
|
460/3
|
108″
|
92″
|
80″
|
4
|
3″
|
SAE50D-3 |
50 Ton
|
175.5
|
208-230/3
|
108″
|
92″
|
80″
|
4
|
3″
|
SAE50D-4 |
50 Ton
|
175.5
|
460/3
|
108″
|
92″
|
80″
|
4
|
3″
|