25Ton to 50Ton Air Cooled Modular Chillers

5 Categories of Modular Chillers
(Click to see category)

 

1.5Ton – 5Ton
Single Circuit
208-230/1
3Ton – 10Ton
Single Circuit
208-230/3 – 460/3
12.5Ton – 20Ton
Single Circuit
208-230/3 – 460/3
10Ton – 20Ton
Dual Circuit
208-230/3 – 460/3
25Ton – 50Ton
Single/Dual Circuit
208-230/3 – 460/3

For higher capacity, view our Multiple Module Configurations up to 200 Tons.

Whaley Modular Chillers are ideal for retrofit installations to replace old, worn out air cooled chillers where pumps and reservoirs are already in existence. Modular chillers can be installed in series and staged in as needed depending upon current load needs. Pump Tank Systems are available as well. contact an experienced modular chiller engineer.

208-230/460/3 Single Circuit 25 Ton – 50 Ton
Unit Specifications

Model #
Tonnage
KW
BTU/hr
Voltage
GPM
Compressors
Unit Amps
(1 On Comp)
Unit Amps
(2 On Comps)
SAE25-3
25 Ton
87.75
300,000
208-230/3
60
2
54.7
109.4
SAE25-4
25 Ton
87.75
300,000
460/3
60
2
21.9
43.8
SAE30-3
30 Ton
105.3
360,000
208-230/3
72
2
62.4
124.8
SAE30-4
30 Ton
105.3
360,000
460/3
72
2
30.2
60.4
SAE40-3
40 Ton
140.4
480,000
208-230/3
96
3
57.9
173.7
SAE40-4
40 Ton
140.4
480,000
460/3
96
3
26.4
79.2
SAE50-3
50 Ton
175.5
600,000
208-230/3
120
3
62.4
187.2
SAE50-4
50 Ton
175.5
600,000
460/3
120
3
30.2
90.6


Single Circuit Physical Specifications

Model #
Tonnage
KW
Voltage
Length
Width
Height
# of
Compressors
Inlet/Outlet
Connections
SAE25-3
25 Ton
87.75
208-230/3
102″
44″
68″
2
2″
SAE25-4
25 Ton
87.75
460/3
102″
44″
68″
2
2″
SAE30-3
30 Ton
105.3
208-230/3
102″
44″
80″
2
2″
SAE30-4
30 Ton
105.3
460/3
102″
44″
80″
2
2″
SAE40-3
40 Ton
140.4
208-230/3
108″
92″
80″
3
3″
SAE40-4
40 Ton
140.4
460/3
108″
92″
80″
3
3″
SAE50-3
50 Ton
175.5
208-230/3
108″
92″
80″
3
3″
SAE50-4
50 Ton
175.5
460/3
108″
92″
80″
3
3″

 

208-230/460/3 Dual Circuit 25 Ton – 50 Ton

Unit Specifications

Model #
Tonnage
KW
BTU/hr
Voltage
GPM
Compressors
FLA
Circuit A
FLA
Circuit B
Unit FLA
SAE25D-3
25 Ton
87.75
300,000
208-230/3
60
2
54.7
54.7
109.4
SAE25D-4
25 Ton
87.75
300,000
460/3
60
2
21.9
21.9
43.8
SAE30D-3
30 Ton
105.3
360,000
208-230/3
72
2
62.4
62.4
124.8
SAE30D-4
30 Ton
105.3
360,000
460/3
72
2
30.2
30.2
60.4
SAE40D-3
40 Ton
140.4
480,000
208-230/3
96
4
84.8
80
164.8
SAE40D-4
40 Ton
140.4
480,000
460/3
96
4
42.4
40
82.4
SAE50D-3
50 Ton
175.5
600,000
208-230/3
120
4
115.8
115.8
231.6
SAE50D-4
50 Ton
175.5
600,000
460/3
120
4
52.8
52.8
105.6


Dual Circuit Physical Specifications

 

Model #
Tonnage
KW
Voltage
Length
Width
Height
# of
Compressors
Inlet/Outlet
Connections
SAE25D-3
25 Ton
87.75
208-230/3
102″
44″
68″
2
2″
SAE25D-4
25 Ton
87.75
460/3
102″
44″
68″
2
2″
SAE30D-3
30 Ton
105.3
208-230/3
102″
44″
80″
2
2″
SAE30D-4
30 Ton
105.3
460/3
102″
44″
80″
2
2″
SAE40D-3
40 Ton
140.4
208-230/3
108″
92″
80″
4
3″
SAE40D-4
40 Ton
140.4
460/3
108″
92″
80″
4
3″
SAE50D-3
50 Ton
175.5
208-230/3
108″
92″
80″
4
3″
SAE50D-4
50 Ton
175.5
460/3
108″
92″
80″
4
3″

For Higher Capacity
Install Whaley Modular Chillers in parallel and stage them in as daily load requirements fluctuate.

 

**Closed Loop Modular Chiller Systems Available as well**